Eaton Tripp Lite Series 1.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA - 8 x NEMA 5-15R - 1.8kVA - 1U Rack-mountable
Key Features
- Single phase 15A 120V Auto Transfer Switch / ATS PDU
- Enables redundant A/B power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
- Two digit visual current meter reports equipment load in amps; Upgrade options available
- TAA Compliant
Specifications 28
| Package Contents |
|
| Product Type | PDU |
| Input Voltage | 120 V AC |
| Manufacturer Part Number | PDUMH15AT |
| Manufacturer Website Address | http://www.eaton.com |
| Marketing Information | Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R outlets, and two 12 ft. 5-15P input power cord. Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS s |
| Limited Warranty | 2 Year |
| Output Voltage | 120 V AC |
| Weight (Approximate) | 11 lb |
| Certifications & Standards |
|
| Management |
|
| Manufacturer | Eaton Corporation |
| Product Model | PDUMH15AT |
| Product Name | PDUMH15AT PDU Metered ATS 120V 15A 8 Outlet |
| Mount Type | Rack-mountable |
| Rack Height | 1U |
| Brand Name | Tripp Lite series |
| Plug/Connector Type | NEMA 5-15P |
| Country of Origin | Taiwan |
| Height | 1.8" |
| Width | 17.5" |
| Depth | 14.5" |
| Receptacle Type | NEMA 5-15R |
| Environmentally Friendly | Yes |
| TAA Compliant | Yes |
| Power Rating (VA) | 1800 VA |
| Receptacle Detail | 8 x NEMA 5-15R |
| Plug/Connector Detail | 2 x NEMA 5-15P |